Lamps do not illuminate when using ATEM switchers

Refer to Connect with Blackmagic Design ATEM to set up. In Setup step 6, if you cannot find the IP address of the station, check “Cannot find the station in FlexTally utility application.” If you were able to finish all setup steps but the lamps do not illuminate at all, see the following troubleshooting steps.

  1. Is the ATEM switcher and station is connected via LAN directly or via a hub?

Please make sure they are connected on a local area network, not via the Internet.

  1. Does the Tally LED on the station illuminate red or green?

In order to check, refer to “Is there any way to check if a switcher is connected properly?

If the Tally LED does not illuminate at all, refer to “Lamps do not luminate or illuminate incorrectly”.

If the Tally LED does illuminate red or green, go to step 3.

  1. Set a fixed IP address that corresponds to the ATEM IP address

Refer to “IP address settings”.

E.g: When the ATEM IP address is 192.168.10.240:

Set the station IP address as –

IP Address: 192.168.10.77

Subnet mask: 255.255.255.0

Default Gateway: 192.168.10.1

After setting, unplug the AC adapter to reboot the station.

*Do not use an IP address that is already used on the same local area network.

* If the station is set to a fixed IP, it’s possible that the station will not be found. Please change the IP address after all settings are complete.

If you want to change the station settings again, the PC should be set to a fixed IP or the station should be initialized to set up again.

  1. Confirm

Unplug the LAN cable between the ATEM switcher and the station to reconnect. Check if the Tally LED on the station illuminates red or green.